INDUSTRIAL POLYCHEMICAL SERVICE -- WELD-ON 3 FOR ACRYLIC -- 8040-00N000090
=====================  Product Identification  =====================

Product ID:WELD-ON 3 FOR ACRYLIC
MSDS Date:06/01/1990
FSC:8040
NIIN:00N000090
=== Responsible Party ===
Company Name:INDUSTRIAL POLYCHEMICAL SERVICE
Address:17109 S MAIN
Box:379
City:GARDENA
State:CA
ZIP:90247
Country:US
Info Phone Num:213-321-6515
Emergency Phone Num:213-321-6515
CAGE:17510
=== Contractor Identification ===
Company Name:IPS CORPORATION
Address:17109 S. MAIN ST.,
Box:379
City:GARDENA
State:CA
ZIP:90248
Country:US
Phone:310-898-3300
CAGE:17510

=============  Composition/Information on Ingredients  =============

Ingred Name:ING 4:ON CONTR LABEL, PROD BULLETINS & OUR SOLV CEMENTING
    LITERATURE. ALL HNDLNG EQUIP SHOULD BE ELECTRICALLY GROUNDED.
RTECS #:9999999ZZ

Ingred Name:VENT:EXHAUST SYSTEMS MAY BE REQD. WHERE EXPLOSIVE MIX MAY
    BE PRESENT, SYSTEMS SAFE FOR SUCH LOCATIONS SHOULD BE USED.
RTECS #:9999999ZZ

Ingred Name:EFTS OF OVEREXP:VOM OCCURS, PROD CAN BE ASPIRATED INTO
    LUNGS CAUSING LUNG INFLAMM/DAM. SKIN:PRLNGD/RPTD CONT MAY (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:CAUSE IRRIT, DEFATTING OF SKIN & DERM. MAY BE
    ABSORBED THRU SKIN. EYES:LIQ MAY CAUSE TEMPORARY IRRIT WITH (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8:TEMPORARY CORNEAL INJURY. VAPS MAY IRRITATE EYES.
    CHRONIC: CHRONIC EXPOS TO METHYLENE CHLORIDE HAVE (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:CAUSED LIVER & KIDNEY DISEASE IN EXPTL ANIMALS.
    INGEST OF ALCOHOL AFTER EXPOS TO TRICHLOROETHYLENE CAUSES (ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10:"DEGREASER'S FLUSH", A FLUSHING & REDDENING OF THE
    FACE, NECK & SHOULDERS.
RTECS #:9999999ZZ

Ingred Name:METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA III).
    BP:104F. VP:352 @ 20C. VAP DENS:2.93. EVAP RATE:14 (BU AC=1)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 90%
OSHA PEL:500 PPM, C, 1000
ACGIH TLV:50 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:TRICHLOROETHYLENE  (SARA III)
CAS:79-01-6
RTECS #:KX4550000
Fraction by Wt: 9%
OSHA PEL:100 PPM/100 STEL
ACGIH TLV:50 PPM/100,A5STEL;93
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Ingred Name:METHACRYLIC ACID, METHYL ESTER; (METHYL METHACRYLATE
    MONOMER) (SARA III)
CAS:80-62-6
RTECS #:OZ5075000
Fraction by Wt: <1%
OSHA PEL:100 PPM
ACGIH TLV:100 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:VOLATILE ORGANIC COMPOUNDS: 160 GRAMS/LITER
RTECS #:9999999VO

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCED SENSIT
    OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR
    EFT IN HUMANS. ADRENOMIMETICS (E.G. EPINEPHRINE) MAY BE
    CONTRAINDICATED EXCEPT FOR LIFE-SUSTAININ G USES IN HUMANS
    ACUTELY/CHRONICALLY EXPOSED TO CHLOROCARBONS . ACUTE: INHAL:EXPOS
    TO VAPS MAY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:DICHLOROMETHANE: GROUP 2B IARC, VOL 7,
    P.194, 1987; ANTIC TO BE CARGIN, NTP 6TH ANNUAL RPT ON CARCINOGENS,
    1991. .
Effects of Overexposure:HLTH HAZ:CAUSE RESP TRACT IRRIT, SIGNS OF NERV
    SYS DEPRESS (DROW/DIZZ/NAUS/HDCH/FATIGUE), ARRHY (IRREG HEART
    BEATS). EXPOS TO HIGH CONC MAY IMPAIR BLOOD'S ABILITY TO TRANSPORT
    OXYGEN. PRLNGD/RPTD EXPO S TO VAPS MAY CAUSE LIVER/KIDNEY DAM.
    INGEST:MAY CAUSE IRRIT TO DIGESTIVE TRACT, SIGNS OF NERV SYS
    DEPRESS. IF (ING 7)
Medical Cond Aggravated by Exposure:INDIVIDUALS W/PRE-EXISTING DISEASES
    OF THE LIVER, KIDNEY OR HEART MAY HAVE INCREASED SUSCEPTIBILITY TO
    THE TOXICITY OF EXCESSIVE EXPOSURES.

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE TO FRESH AIR. IF BRTHG HAS STOPPED, ADMIN ARTF
    RESP. CALL MD. SKIN:REMOVE CONTAMD CLTHG/SHOES. WASH W/SOAP &
    WATER. WASH CONTAMD CLTHG BEFORE REUSE. EYES:FLUSH IMMED W/WATER
    FOR AT LEAST  15 MINS. IF IRRIT PERSISTS, CALL MD. INGEST:DO NOT
    INDUCE VOM. GIVE WATER OR MILK. CONT MD OR POIS CTR IMMED. NOTE TO
    MD:ADRENALIN SHOULD NEVER BE GIVEN TO PERSONS OVEREXPOSED TO THIS
    PROD.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE OR FOAM. WATER MAY BE
    AN INEFFECTIVE EXTINGUISHING AGENT.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESS DEMAND SCBA &
    FULL PROT EQUIP . WATER SPRAY MAY BE USEFUL IN MINIMIZING VAPS &
    COOLING CONTRS EXPOSED TO HEAT/FLAME.(SUP DAT)
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
    INCLUDE HCL & PHOSGENE . AVOID HOT SURFACES & OTHER SOURCES OF
    IGNITION.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVAC AREA, VENT & AVOID BRTHG VAPS. DIKE AREA
    TO CONTAIN SPILL. CLEAN UP AREA (WEAR PROT EQUIP) BY MOPPING OR
    W/ABSORB MATL & PLACE IN CLSD CONTRS FOR DISP. AVOID CONTAM OF
    GROUND & SURF WATERS. DO NO T FLUSH TO SEWER. IF SPILL OCCURS
    (SUPPDATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN SHADE BETWEEN 40F-110F. KEEP
    AWAY FROM HEAT/SPARKS/OPEN FLAME/OTHER SOURCES OF IGNIT. AVOID
    PRNGLD BRTHG OF VAPS. USE W/ADEQ VENT.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GEN VICINITY
    OF ARC WELDING, OPEN FLAMES OR HOT SURF. HEAT &/OR UV RADIA MAY
    CAUSE FORMATION OF HCL &/OR PHOSGENE . AVOID CONT W/EYES, SKIN &
    CLTHG. TRAI N EMPLOYEES ON ALL SPEC HNDLNG (SUP DAT)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IN SITUATIONS WHERE VAPOR CONCENTRATIONS EXCEED
    THE RECOMMENDED EXPOSURE LIMITS, A NIOSH/MSHA APPROVED ORGANIC
    VAPOR CARTRIDGE RESPIRATOR W/FULL FACE-PIECE IS RECOMMENDED. USE
    ONLY NIOSH/MSHA APPROVED  SCBA FOR EMERGENCIES.
Ventilation:IF CURRENT VENT PRACTICES ARE NOT ADEQ TO MAINTAIN AIRBORNE
    CONC BELOW ESTABLISHED EXPOS LIMITS, ADDNL VENT OR (ING 6)
Protective Gloves:PVA COATED GLOVES.
Eye Protection:CHEM WORK GOG & FULL LNGTH FCSHLD.
Other Protective Equipment:IMPERVIOUS APRON & A SOURCE OF RUNNING WATER
    TO FLUSH OR WASH EYES & SKIN IN CASE OF CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPEC GRAV:TYPICAL 1.284-1.364 @ 71-75F. FIRE FIGHT PROC:AVOID SPREADING
    BURNING LIQ W/WATER USED FOR COOLING PURPOSES.  SPILL PROC:INDOORS,
    TURN OFF HEATING &/OR AIR CONDITIONING SYS TO PVNT VAPS FROM 
    CONTAMINATING ENTIRE BLDG. OTHER PREC:PROCS BEFORE THEY WORK W/THIS
    PROD. FOLLOW ALL PRECAUTIONARY INFO GIVEN (ING 5)

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:INGRED 1
Vapor Pres:INGRED 1
Vapor Density:INGRED 1
Spec Gravity:SUPP DATA
Evaporation Rate & Reference:INGRED 1
Solubility in Water:SLIGHTLY MISCIBLE
Appearance and Odor:CLEAR, THIN LIQUID; CHARACTERISTIC ODOR OF
    CHLORINATED SOLVENTS.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, OXYGEN, NITROGEN PEROXIDE, POTASSIUM & REACTIVE
    METALS.
Stability Condition to Avoid:STABLE UNDER NORM CNDTNS OF STOR & HNDLNG.
    AVOID CONT W/OPEN FLAME, ELEC ARCS, HOT SURF WHICH CAN CAUSE
    THERMAL DECOMP.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY YIELD CARBON
    MONOXIDE, CARBON DIOXIDE, PHOSGENE &/OR HYDROGEN CHLORIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:RECOVERED LIQUIDS MAY BE SENT TO A LICENSED
    RECLAIMER OR INCINERATION FACILITY. CONTAMINATED MATERIAL MUST BE
    DISPOSED OF IN A PERMITTED WASTE MANAGEMENT FACILITY. CONSULT
    FEDERAL, STATE OR LOCAL DISP OSAL AUTHORITIES FOR APPROVED
    PROCEDURES.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.